Main Characteristics: 1, Using fever of gasifying unites burning technology. It applied to burn various kinds of medical waste, such as syringes, infusion set, disposable dressing, and also small animal, some city waste, like paper, tree leaves. 2, Closed vacuum-wide operation, applicable to treat infectious medical waste and to prevent secondary pollution. 3, Whole design, e...
Read More
Containerized Mobile Type Animal Waste Incinerator Model CA30
Incinerator Model CA30, Overview This model is small-scale animal cremation equipment. Construction is dual/double combustion chamber with 02 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 330Liters (Model CA30). Primary & Secondary combustion chambers and smoke filter chamber with firebrick and refractory concrete chamber. Batch load on...
Read More
Waste Incinerator Model TS100 PLC
Items/Model TS100(PLC) Burn Rate (Average) 100 kg/hour Feed Capacity(Average) 200 kg Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14--28...
Read More
Waste Incinerator Model TS50 PLC
Items/Model TS50(PLC) Burn Rate (Average) 50 kg/hour Feed Capacity(Average) 100kg Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1--24...
Read More
Waste Incinerator Model TS30 PLC
Items/Model TS30(PLC) Burn Rate (Average) 30 kg/hour Feed Capacity(Average) 60kg Control Mode PLC Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) 10.2--20 ...
Read More
Waste Incinerator Model TS20 PLC
Items/Model TS20(PLC) Burn Rate (Average) 20 kg/hour Feed Capacity(Average) 40kg Control Mode PLC Combustion Chamber 210L Internal Dimensions 65x65x50cm Secondary Chamber 110L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) 7.8--16.3 ...
Read More
Waste Incinerator Model TS10 PLC
Items/Model TS10(PLC) Burn Rate (Average) 10 kg/hour Feed Capacity(Average) 20kg Control Mode PLC Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) 5.4--12.6 ...
Read More
Waste Incineration Treatment Model TS75(PLC)
Ecolead Technology(Nanjing) Co.,Ltd. (ECOLEAD), supply system solutions for air filters and medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project, clean room products, auto roll filters. Nanjing Clover Medical Technology Co.,Ltd. (HICLOVER) is our sister company focus on export business. Items/Model ...
Read More
250kgs per hour capacity waste incinerator
Incinerator Model TS250 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambersand smoke filter chamber. Batch load on the bottom of chamber....
Read More
Waste Incineration Treatment Diesel Oil type Model TS150
Waste Incineration Treatment Diesel Oil type Model TS150Main Parts List as below:Primary combustion chamberSecondary combustion chambersmoke filter chamberincinerator PLC control casechimney, 10meters, stainless steelItaly Oil fule burneroil tank 300literswith full spare parts: oil burner, air blower, temperature thermocouple
Read More
incinerator manufacturer 200kgs/h
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste:* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load* A burner of l...
Read More
Controlled Air Incinerator Plant
WASTE CONTAINERS SET160 LITERS WASTE AUTOCLAVE AND SCHREDER30 - 50 kg/h DIESEL INCINERATORWASTE SCHREDERWater, mixed up with powders, falls in a decanter built with carbon steel sheets. Particles decant while water continues its circu...
Read More
Medical waste incinerator for sale
Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint.Internal surface of incinerator should be line with noncracking refractory bricks made of ceramics&n...
Read More
Smallest Waste Incinerator Model YD-10
Item Specification Model YD-10 Main Product List Combustion Chamber Control Case Stack: 3.0Meters Oil burner: 02 units Oil Tank (if oil fuel):50Liters Equipment Technical Specifications Model YD-10 Picture ...
Read More
TS100 Model incinerator
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS100 Burn Rate ...
Read More
Waste incinerator combustion chamber firebrick
waste incinerator combustion chamber firebrickWWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com  ...
Read More
Double chamber incinerator
Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent &...
Read More
Waste Incinerators Specification
To provide for diesel service tank (Capacity 400 litres) including level indicatorThe tank should be connected to the incinerator at a higher level to enable free-flow of diesel from the tank to the incinerator. The connecti...
Read More
Waste Incinerator
A ready built fabricated room shall be supplied for housing the incinerator. The room will be designed in such a way that free space is available on all sides and heat radiation kept at minimum and giv...
Read More
Domestic Waste
Waste Type: Domestic Waste Average Emissions Rates: Not to exceed EU Standard Limits (Total dust "mg/m3": 30; Sulphur Dioxide: 200;Nitrogen Dioxide: 400; Carbon Monoxide: 100) Minimum Burn Rate: 2,000 kg per day (up to 1,500-person camp); top...
Read More