Medical waste incinerator for sale

Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint.Internal surface of incinerator should be line with noncracking refractory bricks made of ceramics&n...
Read More

Smallest Waste Incinerator Model YD-10

Item Specification Model YD-10 Main Product List Combustion Chamber Control Case Stack: 3.0Meters Oil burner: 02 units Oil Tank (if oil fuel):50Liters Equipment Technical Specifications Model YD-10 Picture ...
Read More

TS100 Model incinerator

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.Tel:  +86-25-8461 0201   Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS100 Burn Rate ...
Read More

Waste incinerator combustion chamber firebrick

waste incinerator combustion chamber firebrickWWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.Tel:  +86-25-8461 0201   Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com  ...
Read More

Double chamber incinerator

Construction   Constructed from heavy duty mild or aluminized steel  or equal and approved equivalent                                     &...
Read More

Waste Incinerators Specification

To provide for diesel service tank (Capacity 400 litres) including level indicatorThe tank should be connected to the incinerator at a higher level to enable free-flow of diesel from the tank to the incinerator. The connecti...
Read More

Waste Incinerator

A ready built fabricated room shall be supplied for housing the incinerator. The room will be designed in such a way that free space is  available  on all sides and heat radiation  kept at minimum and giv...
Read More

Domestic Waste

Waste Type: Domestic Waste Average Emissions Rates: Not to exceed EU Standard Limits (Total dust "mg/m3": 30; Sulphur Dioxide: 200;Nitrogen Dioxide: 400; Carbon Monoxide: 100) Minimum Burn Rate: 2,000 kg per day (up to 1,500-person camp); top...
Read More

Technical Specifications for Portable Incinerators

The Chamber volume of approximately 0.37m3 and a1  combustible load volume (volume of material) ofapproximately 0.30 m32  Burner power of approximately 189,000kcal/hourMaximum Combustion Temperature of up to 1250Degree CelsiusType of emitted Ga...
Read More

MEDICAL/BIOLOGICAL WASTE INCINERATOR

SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE  INCINERATOR It should  be  a three chambered incinerator  The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other ope...
Read More

incinerator to burn nearly 10ton(10,000kg) of tobacco waste

Incinerator to burn nearly 10ton(10,000kg) of tobacco waste dust) from a tobacco processing plant. Requirements: 1.Incinerator system complete with scrubber, pollution control system, water system, loading system, ash removing system and if  anythi...
Read More

Solid waste incinerator placed in a container

Solid waste incinerator, productivity 100kg/h placed in a container.  Dimensions: 2,45x12,2m and 2,9m in height.   Operates natural gas with the pressure of 0.005 MPa and consumption of 0,21-0,23 m3 per kg of waste. Instal...
Read More

Double Combustion Chamber Incinerator

● Double Combustion Chamber All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly.  ● Containerized Mobile Incinerator The incinerator mounted in ISO Container before lea...
Read More

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORSMedical Waste Incinerator, 100 to 120 Kg/hrApplication   For incineration, general and pathologicalCapacity    100 C 120 kg/h burn rateType Two  combustion chambers type; p...
Read More

Mobile Incinerator Containerized Incinerators Units

Mobile Incinerator Units to properly incinerate Solid Waste, Petroleum Oil, and Lubricants. Each Unit will be in accordance to the technical specifications/ operational capacity as defined below. Additionally, each Unit will provide Operat...
Read More

Automating all operations of the incinerator

automating all operations of the incinerator Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalentInsulation Refractory material liningCombustion Temperatures   Above 850 0C, controlled electronicallyGas residue&nb...
Read More

SPECIFICATIONS OF A HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

Capacity of destruction in weight: 60 Kg/h. 2.      It should be able to operate not less than 10 hours/day 3.      This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.      Design Specification : Types A, B, C, D, and E of medical waste...
Read More

Double chamber incinerators

2.) Size requirement for the incinerators is 750 -- 850 kg capacity3.) The bum rate should be 80 LL 100 kg/ hour.4) The primary chamber shouId have an operating temperature of 900 -1200 degree C.5) The incinerator ...
Read More

The incinerator with “PYROLYTIC” combustion

The incinerator control panel shall have all appropriate audible and visual alarms to ensure safe operation. This incinerator with “PYROLYTIC” combustion must have: 1.A combustion chamber of waste: oPerfectly tight door for the manual...
Read More

Industrial MultiWaste Incinerator System

Design, installation and commissioning of multi industrial waste incinerator. Capacity: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with dual chamber system)1st chamber-870 Deg.C - 900 Deg.C2nd chamber-1000 deg.C – 1200 De...
Read More